Section 2: Using the WinDGS Utilities
23
9. Navigate through the Aironet Access Point menu to
the link test option. See the appropriate Access
Point Technical Reference Manual for more infor-
mation.
10. Set up the test options to accurately model the
system.
11. Set the test for continuous operation with a
1-second delay.
12. Begin traversing the area around the Aironet
Access Point to determine its coverage. If logging
and notes are not possible with the telnet applica-
tion, maintain a manual log.
The telnet session packets are interspersed with test
packets which may increase the round-trip time for some
frames. The link test will show progress changes as the test
is being conducted.
The first-time delivery success rate for the packet may not
be important for transaction-based systems, and can result
in a slightly larger range. Using longer packets can provide
some degree of safety margin in the range estimate.
NOTE: Roundtrip time will be affected by the telnet
session maintenance.
Vedere la pagina 28